Fire Suppression Solutions for Electrical EquipmentB2B Project Support Wenzhou Ritchwave Electric Co., Ltd.

Thermal aerosol fire extinguishing device

Compact fire suppression for electrical enclosures.

Automatic thermal activation, fast aerosol discharge and localized protection—without external pipework or a stored-pressure cylinder.

Get Product Recommendation Send us your enclosure size and application.
Thermal aerosol fire extinguishing device discharging inside an electrical cabinet during a fire
Thermally activated aerosol suppression in operationElectrical enclosure protection
≤ 6 SEC
DISCHARGE
0.10 m³Protected volume
≥170°CThermal activation
−50 to +110°COperating range
10 yearsListed service life

Why TAF series

Put suppression close to the risk.

Designed for initial fires in small, reasonably enclosed spaces, the TAF-series unit installs directly inside equipment where electrical faults can begin.

01

Automatic thermal response

The device activates when its specified thermal threshold is reached, providing localized action without waiting for manual intervention.

02

Fast condensed aerosol discharge

The manual lists a discharge time of no more than six seconds for rapid distribution inside a suitable enclosure.

03

No external pipework

A self-contained format reduces installation complexity in compact panels and equipment compartments.

04

Compact installation

The 78 × 51 × 29 mm housing supports 35 mm DIN rail mounting or adhesive-backed installation on a suitable surface.

Ritchwave manufacturing

From production floor to export shipment.

Ritchwave supports industrial electrical projects with organized manufacturing, assembly, inspection, packaging and export processes. Our production environment is structured to help maintain consistency from order confirmation through final delivery.

01ProductionControlled manufacturing
02AssemblyComponent integration
03InspectionQuality verification
04Packaging & ExportPrepared for delivery
Talk directly with our factory team.

Request production information, product photos or project support before ordering.

Chat with Ritchwave on WhatsApp
DIN rail mounted aerosol fire suppression device in an electrical panel

Typical applications

For compact, enclosed equipment.

Application suitability depends on protected volume, enclosure leakage, airflow, internal layout and the actual fire risk.

Distribution cabinetsLocalized protection near electrical connections
SwitchgearCompact integration inside enclosures
Control panelsProtection for PLC and automation hardware
Battery enclosuresRapid response inside compact housings
Equipment compartmentsClose to identified ignition points
Custom enclosuresReviewed according to layout and volume
Important: the device is not intended for open or heavily ventilated spaces and does not replace required building fire alarm or fixed fire protection systems.

Technical specifications

Key product data.

The TAF series is available in five extinguishing-agent sizes. Reference values below are taken from the supplied 10 g technical manual; final specifications and selection must be confirmed for the ordered model and actual installation.

Available agent sizes10G / 20G / 30G / 40G / 50G
Reference agent weight10 g ± 1 g
Recommended density100 g/m³
Reference protected volumeUp to 0.10 m³ (10G)
Reference dimensions78 × 51 × 29 mm
Reference total weight75 g
Activation temperature≥170°C
Discharge time≤6 seconds
Operating temperature−50°C to +110°C
Service life10 years

Installation overview

Simple mounting. Careful application review.

Isolate the equipment

Disconnect power and verify the equipment is de-energized.

Calculate protected volume

Measure usable internal volume and assess ventilation and leakage.

Select the position

Place near the upper area and likely ignition source with an unobstructed outlet.

Secure the device

Mount on a 35 mm DIN rail or a clean, suitable adhesive surface.

Complete inspection

Verify mounting, clearance, environmental conditions and installation date.

Request product selection support

Tell us about your enclosure.

Share a few project details. Ritchwave can review the application and respond with a suitable product recommendation and quotation.

  • Enclosure dimensions and internal volume
  • Equipment type and operating temperature
  • Installation country and project quantity
  • Photos or drawings, if available
WhatsApp +86 135 7542 0134

Get a Quote

Fields marked * are required.

Your details will only be used to respond to this product inquiry.

Frequently asked questions

Before you request a quote.

Is the TAF-series device automatic?

Yes. It is thermally activated. The current manual lists a start-up temperature of at least 170°C. Placement must be suitable for the application.

Does it require external piping or a pressure cylinder?

No. The unit is self-contained and requires neither external discharge pipework nor a stored-pressure extinguishing-agent cylinder.

What volume can one unit protect?

The current manual lists a protected volume of up to 0.10 m³ for the specified 10 g unit at a recommended density of 100 g/m³. Actual suitability must be validated.

Can it be used in an open space?

No. The product should not be used in open or heavily ventilated spaces.

Can it be reused after discharge?

No. It is a single-use device and must be replaced after activation.

WhatsApp